SIL4 train control system which is meant for trains equipped with ETCS running on lines where national Legacy System needs to be operated.

BTM/LTM Antenna

DESCRIPTION
- Energizes the balise
- Acquires the telegrams transmitted from balise and Euroloop
- Auto-diagnostic
- Functioning temperature: -40°C to 70°C
DIMENSIONS (W x H x D)
384 x 484 x 121 mm
POWER SUPPLY
24 Vdc
European Vital Computer (EVC)

DESCRIPTION
- Realizes odometer functionality
- Executes the software application
- Collects all the diagnostic information
- Auto-diagnostic
- Functioning temperature: -25°C to 70°C
DIMENSIONS (W x H x D)
530 x 500 x 348 mm
POWER SUPPLY
24 Vdc
DMI/MMI

DESCRIPTION
- Interfaces with the engine-driver
- Auto-diagnostic
- Functioning temperature: -25°C to 70°C
DIMENSIONS (W x H x D)
270 x 210 x 58 mm
POWER SUPPLY
24 Vdc